The HCA-BARO pressure sensors perform precision digital signal conditioning and provide analogue and digital output at the same time. The sensors are calibrated, temperature compensated and linearised and are intended to be used for barometric air pressure measurement. Miniature SMT and SIL housings allow for space-saving PCB-mounting and maximum OEM design flexibility. All HCA-BARO pressure sensors can be modified according to customer specific requirements.
Typical applications include weather stations, environmental data loggers, altimeters, hydrology as well as compensation of atmospheric pressure changes for industrial systems and instrumentation equipment.
Pressure ranges | Absolute | 600...1100 mbar, 800...1100 mbar |
Output signal | 0.25...4.25 V, I²C bus | |
Total accuracy incl. temperature effects (max.) | ±1 %FSS | |
Pressure connection | tube fitting (Ø 2 mm) | |
Size without nipples and pins (approx.) | 13 x 16 x 7 mm |
Product request
In a few steps quickly and conveniently to the right product.
Please search by complete product numbers, e.g. CTE7005GY4 or 501430. In order to increase the number of search results, please search by part of the product number only, e.g. CTE7.